Maverick Long Cuff Nitrile Powder Free Glove Extra Small

Item No. 1440845
Maverick LC Nitrile Exam Gloves Long Cuff  Fingertip textured Powder Free Not made with natural rubber latex Chemo drugs tested Ambidextrous Long Cuff Aqua blue colour GLOVE PROPERTIES MEASUREMENT (MM) Length ≥280 Thickness at Palm (centre of Palm) 0.09 ± 0.02 Thickness at Finger (13mm ± 3mm from
Read full description
This product cannot be ordered at the moment.
Description
Maverick LC Nitrile Exam Gloves Long Cuff 
  • Fingertip textured
  • Powder Free
  • Not made with natural rubber latex
  • Chemo drugs tested
  • Ambidextrous
  • Long Cuff
  • Aqua blue colour
GLOVE PROPERTIESMEASUREMENT (MM)
Length≥280
Thickness at Palm (centre of Palm)0.09 ± 0.02
Thickness at Finger (13mm ± 3mm from tip)0.14 ± 0.02
PHYSICAL PROPERTIESBEFORE AGEINGAFTER AGEING
Tensile Strength (MPa)≥18≥16
Elongation (%)≥500≥500
Elongation after Isopropanol immersion (%)≥500N/A
INSPECTION LEVELS AND AQLINSPECTION LEVELAQL
WatertightnessG11.5
Physical DimensionsS24.0
Tensile StrengthS24.0
Visual Inspection (Major)S42.5
Visual Inspection (Minor)S44.0
Particulate ResidueN=5≤2mg/glove
PACKAGING 
Configuration
100 gloves per box for XS to XL
80 gloves per box for XXL
10 boxes per carton
REGULATORY COMPLIANCE 
RegulationsARTG 164563
MDD 93/42/EEC
REACH
ROHS Directive 2002/95/EC
EU 10/2011
EC 1935/2004
EU 2016/425
INTERNATIONAL STANDARDS 
StandardsASTM D6319
ASTM D5151
ASTM D6124
ASTM D6978
EN ISO 374-1 (Type B)
EN 16523-1
EN 374 part 2, 3, 4 & 5
EN 420
EN 455 part 1, 2, 3 & 4
EN 1186
EN 13130
CEN/TS 14234
NFPA 1999
ISO 10993 part 5 & 10
HACCP Certified
MANUFACTURING ACCREDITATIONS 
AccreditationsISO 9001
ISO 13485
EN ISO 13485
CHEMOTHERAPY DRUGS AND CONCENTRATION
(TESTED FOR RESISTANCE TO PERMEATION BY CHEMOTHERAPY DRUGS AS PER ASTM D6978-05, TEST REPORT PN 101567)
MINIMUM BREAKTHROUGH DETECTION TIME (MINUTES)
Carmustine (BCNU), 3.3mg/ml (3,300ppm)15.1
Cisplatin, 1.0mg/ml (1,000ppm)>240
Cyclophosphamide (Cytoxan), 20.0mg/ml (20,000ppm)>240
Dacarbazine (DTIC), 10.0mg/ml (10,000ppm)>240
Doxorubicin Hydrochloride, 2.0mg/ml (2,000ppm)>240
Etoposide (Toposar), 20.0mg/ml (20,000ppm)>240
Fluorouracil, 50.0mg/ml (50,000ppm)>240
Methotrexate, 25.0mg/ml (25,000ppm)>240
Mitomycin C, 0.5mg/ml (500ppm)>240
Paclitaxel (Taxol), 6.0mg/ml (6,000ppm)>240
Thiotepa, 10.0mg/ml (10,000ppm)30.8
Vincristine Sulfate, 1.0mg/ml (1,000ppm)>240
WARNING: Carmustine and Thiotepa, at the tested concentration, degraded a Maverick LC nitrile glove at 15.1 minutes and 30.8 minutes respectively. The safe use of gloves in chemotherapy treatment is solely the decision of clinicians authorised to make such a decision.



    Loading